PyroGuard CRFR™ coveralls are designed to wear over your primary FR garments, helping to extend the life of your primary FR clothing. Coveralls also offer protection from a broad range of chemicals and provide flash fire protection that meets NFPA 2113. Our advanced, self-extinguishing fabric does not melt or drip when ignited to prevent flames from spreading. An attached respirator hood combined with secure, elastic wrists help prevent inhalation of toxic chemicals while keeping contaminants from entering the coveralls. PyroGuard CRFR® Coveralls stop flames and chemicals in their tracks offering the comfort and safety you need to work in tough environments.
- Proprietary bi-laminate fabric protects against flames and chemicals
- Elastic back stretches with user for more comfort and better tear resistance
- Storm flap over zipper adds an extra layer of protection
- Taped seams offer added protection over serged seam coveralls
- Attached respirator hood helps prevent inhalation of toxic chemicals
- Possible applications include petrochemical environments, manufacturing, industrial, and oil / gas
Pack Type | Bulk |
---|---|
Sterile | No |
Color | Green |
Collar / Hood Type | Attached Hood |
Ankle Style | Elastic Ankle |
Cuff Style | Elastic Wrist |
Material | Bi-Laminate Chemical & Flame Resistant Fabric |
Seam Style | Taped Seams |
Closure Type | Zipper w/storm flap |
Test Conducted | Test Method | Results |
---|---|---|
Grab/Tensile - Machine Direction | ASTM D1117 / D1682 | 34 lbs. |
Grab/Tensile - Cross Direction | ASTM D1117 / D1682 | 27 lbs. |
Bond Strength - Machine Direction | IST 110.2 | 197 gms |
Bond Strength - Cross Direction | IST 110.2 | 223 gms |
Mullen Burst | ASTM D3786-87 | 35 psi |
Resistivity Machine Direction | IST 70.1 | 2.9 x109 ohms |
Resistivity | IST 70.1 | 3.1 x109 ohms |
CHEMICAL | Penetration ASTM F903 Time to Penetrate (minutes) | Permeation ASTM F739 Normalized Breakthrough (minutes) |
---|---|---|
Acetone | >60 | 12 |
Acetonitrile 90% | >60 | IMB |
Acetaldehyde | >60 | NT |
Acrylonitrile | >60 | NT |
Benzene | >60 | NT |
Carbon Disulfide | >60 | 9 |
Crude Oil | >60 | 9 |
Dichloromethane | 2 | IMB |
#1 Diesel | >60 | 15 |
Diethylamine | >60 | IMB |
Dimethylformamide | <1 | IMB |
Ethyl Acetate | >60 | 16 |
Ethylene Dichloride | >60 | NT |
Ethylene Oxide | >60 | NT |
Gasoline | >60 | NT |
Hexane | >60 | >480 |
Hexamethylene Diisocyanate | >60 | 15 |
Hydrochloric Acid | >60 | NT |
JP-8 | >60 | NT |
Jet Fuel A | >60 | NT |
Methanol | >60 | IMB |
Methyl Isobutyl Ketone | >60 | NT |
Methyl Mercaptan | >60 | NT |
Monochlorobenzene | >60 | NT |
Nitric Acid 70% | >60 | 129 |
Nitrobenzene | 3 | 4 |
n-Butyl Acetate | >60 | NT |
Orthodichlorobenzene, Grade F | >60 | NT |
Para-Dichlorobenzene | >60 | NT |
Pentane | >60 | NT |
Phenol | >60 | NT |
Phosporic Acid 85% | >60 | >480 |
Sodium Hydroxide 40% | >60 | >480 |
Styrene | >60 | <1 |
Sulfuric Acid 96% | 45 | 38 |
Tetrachlorethylene | >60 | >480 |
Tetrahydrofuran | <1 | <1 |
Toluene | >60 | 6 |
Trichlorobenzene Mixture | >60 | NT |
Xylene | >60 | NT |
Test Conducted | Test Method | Results |
---|---|---|
Vertical Flammability | ASTM 6413 | Pass |
After Flame | ASTM F1930 | |
Thermal Protective Performance - Spaced | NFPA 1971 - 97 | 6.8 TPP |
Thermal Mannequin Test % Body burn - Machine Direction | ASTM 1903 - 3.5 sec. Over Nomex IIIA garment 6.0 oz/yd2
|